Vacuum & Process Equipment

Provides technology and experience in sputtering, CVD, vacuum drying, and heat treatment systems for semiconductor and display processes.

Sputtering · CVD · Vacuum Dryer · RTP

Cluster Sputtering System(2005)

Introduction to the vacuum equipment sector

Cluster Sputtering System(2005)

Cluster Sputtering System(2005)
  • Cluster sputtering system
  • PM / TM / LL
  • Substrate : 370 x 470 glass
  • Cryo pump / dry pump

Batch Type Sputtering System

Batch Type Sputtering System
Batch Type Sputtering System
Batch Type Sputtering System
  • Batch type sputter for mass production
  • Cell phone EMI shield coating
  • Cryo pump / Dry pump

Co-Sputtering System

Co-Sputtering System
Co-Sputtering System
  • DC & Pulsed DC Sputter
  • 4” Sputter source
  • Substrate 100 x 100 glass
  • LL & PM chamber
  • Magnet bar return (auto).
  • Turbo pump / Rotary pump
  • Throttle valve

Co-Sputtering System

Co-Sputtering System
Co-Sputtering System
  • 6” Co-sputter
  • Bottom up sputtering
  • RF generator(13.56MHz)
  • DC Pre-cleaning (substrate)
  • Substrate 6”
  • Halogen lamp heating(600 °C)

Inline Sputtering System

Inline Sputtering System
Inline Sputtering System
Inline Sputtering System
  • Substrate : 370x470 glass
  • Sputtering(Pulsed DC)
  • IR Heating
  • Substrate transfer module

RF Sputtering System

RF Sputtering System
  • Substrate 100 x 100 glass
  • L/L & 2 PM chamber
  • 8” RF Circular Magnetrons sputter

RF Reactive Sputtering System

RF Reactive Sputtering System
RF Reactive Sputtering System
  • RF Sputter for R&D
  • 4” Sputter source.
  • Turbo pump / Rotary pump
  • Throttle valve

Roll to Roll Sputtering System

Roll to Roll Sputtering System
Roll to Roll Sputtering System
  • FCCL(Flexible PCB)
  • Cu Sputtering
  • Ion source pretreatment
  • PI Film(500mmW)

Roll to Roll Coater

Roll to Roll Coater
Roll to Roll Coater
CVD source · Dual rotary cathode method PECVD
CVD source · Dual rotary cathode method PECVD
IBAD · Low-damage thin film coating using ion beam
IBAD · Low-damage thin film coating using ion beam
UBM · Unbalanced Magnetron Sputter
UBM · Unbalanced Magnetron Sputter
  • Roll to Roll CVD & PVD deposition equipment
  • PET film 500mmW
  • Web speed : 0.1 ~ 10 m/min
  • R2R CVD Source
  • Ion beam assist sputter source
  • Linear thermal source
  • Turbo pump / Dry pump
  • CVD source

PECVD using dual rotary cathode method

  • IBAD(Ion Beam Assistance Deposition)

Sputtering low damage thin film using ion beam
Coating

  • UBM(Unbalanced Magnetron Sputter)

Roll to Roll Sputtering System

Roll to Roll Sputtering System
Roll to Roll Sputtering System
Roll to Roll Sputtering System
Roll to Roll Sputtering System
  • 4 Sputtering Source
  • 1 Dual Magnetron Sputtering Source
  • 1 Ion source
  • IR Heater
  • Film(1300mmW, 188um)
  • Uniformity : TD (±5.0%), MD (±3.0%)
  • TD direction (Transverse Direction): Width direction of the film, MD direction (machine Direction): Film direction (length)

Roll to Roll Degassing System

Roll to Roll Degassing System
Roll to Roll Degassing System
  • Film Degassing System
  • Polyimide film (max. 500 mmW)
  • FIR heater, EPC driving, Tension control
  • Polycold, cryo pump, dry pump

Multi-Sputtering System

Multi-Sputtering System
Multi-Sputtering System
Multi-Sputtering System
  • DC & Pulsed DC Sputter
  • 8” Circular sputter source
  • 4” Ion source
  • Substrate : 6” wafer x 12ea
  • Cryo pump / Dry pump
  • Throttle valve

Hot-wire CVD(Cat CVD) System

Hot-wire CVD(Cat CVD) System
Hot-wire CVD(Cat CVD) System
Hot-wire CVD(Cat CVD) System

Showerhead

Tungsten wire

AL chamber

ESC chuck

  • Hot wire CVD :
  • W(tungsten wire, Ø 0.7, 5N(99.999%), 2,000°C
  • Showerhead
  • Substrate : 370 x 470 glass
  • Turbo pump / Dry pump

VCD_Vacuum Dryer(Mobile Display)

VCD_Vacuum Dryer(Mobile Display)
VCD_Vacuum Dryer(Mobile Display)
VCD_Vacuum Dryer(Mobile Display)
  • Touch screen panel process (Glass)
  • Tray size : 500 x 600
  • Solvent removal in vacuum after PR application
  • Multi chamber & transfer module
  • Dry pump

VCD_Vacuum Dryer(2006)

Equipment configuration

VCD_Vacuum Dryer(2006)
Chamber Unit · N2 Purge&Vent Unit · Frame Unit · Vacuum Unit
  • Touch screen panel process
  • Glass size : 7G(1950 x 2250 mm)
  • Solvent removal in vacuum after PR application
  • Multi chamber
  • Dry pump

Vacuum drying process flow

Vacuum drying process flow chart
Vertical axis: Vacuum degree (Torr) · Horizontal axis: Time (sec)

RTP System

RTP System
RTP System
  • RTP(Rapid Thermal Process)
  • Max 800°C/sec.
  • Substrate 100 x 100 glass
  • RTP(Rapid Thermal Process)
  • Max 1000°C/30sec.
  • Substrate 2” wafer

E-beam Evaporator

E-beam Evaporator
  • Mass production equipment for optical coating
  • E-beam source
  • Diffusion pump / RP & BP
  • Thickness monitor
  • Polycold

Pre-Cleaning System

Pre-Cleaning System
Pre-Cleaning System
Pre-Cleaning System
Pre-Cleaning System
Pre-Cleaning System
  • 4” RF Co- sputtering system
  • 4” VHF(60MHz) pre-cleaning system
  • Substrate : 4” wafer

Aerosol Deposition

Aerosol Deposition
Aerosol Deposition
Aerosol Deposition

Photo of Aerosol Deposition Process Chamber

  • Room temperature formation of ceramic-polymer composite thick film by aerosol deposition process

Aerosol Deposition Schematic Diagram